LUS-75 Limited Use System

Ahead Sanitation Systems is recognized worldwide as the Premier Designer,
Manufacturer and Distributor of NEXT GENERATION Sewage Treatment Systems,
Products and Supplies for the Marine and Recreation Industry.

LIMITED USE SYSTEM CAMP UNIT

The LUS-75 is approved by the Louisiana Department of Health and Hospitals as a Limited Use Treatment System.

is the #1 Choice of Marine Sanitation Devices in the #2 Business SIMPLE, RELIABLE, EFFICIENT & COST EFFECTIVE

How The Ahead Tank Works

 is a biological aerobic (bacteria and air) Type II Marine Sanitation Device. Liquid and solid waste are removed from the water by bacteria naturally contained in sewage. The AHEAD TANK makes perfect environmental sense by working with nature to accelerate the normal biological process. With the addition of oxygen, the natural occurring bacteria breaks down and digest the solids. A mild disinfectant is added to kill any disease-causing bacteria prior to being discharged. AHEAD TANK has no moving parts that comes in contact with the sewage. This biological aerobic process is simple, effective, and ensures Reliable Odor Free Operation.

The Ahead Tank Biological Waste Treatment Process

AERATION CHAMBER

Sewage is aerated as soon as it enters the Aeration Chamber and mixes with the aerated liquid already in the Aeration Chamber. A fine bubble EPDM air diffuser injects air near the bottom of the Aeration Chamber so that the sewage remains in a state of aerobic decomposition. This aerated liquid contains the bacterial sludge that reacts with the sewage to start the reduction process. This movement created by the injected air helps mix the sewage with the bacterial sludge and prevents sludge and sewage solids from settling to the bottom. The air discharged from the surface of the liquid in the Aeration Chamber is vented to the atmosphere through a 1 ½’ FPT connection clearly labeled VENT in black on both sides of the tank.

CLARIFICATION CHAMBER

The liquid displaced from the Aeration Chamber flows through small specially drilled holes at the front bottom side of the Clarification Chamber for further treatment. The suspended material and sewage solids that are too large to pass through the holes remain in the Aeration Chamber to be further reduced in size, as it continues to be mixed with the remaining aerated liquid and bacteria sludge. The liquid sludge and smaller waste material that enters the Clarification Chamber through the small holes is re-moved as the liquid flows upward through some biological filter media located inside the Clarification Chamber. Bacteria will grow on the surface of this biological filter media and produces a sticky, slimy film film that traps small particles of waste. Then the bacteria will consume the trapped particles of waste as their food supply. By the time the liquid reaches the top of the biological filter media it has passed through several layers of bacteria, ensuring that the sludge and waste removal process is completed. Any floating particles of waste that was not trapped and consumed by the bacteria that reaches the top of the biological filter media will be returned to the Aeration Chamber by means of an internal air lift pump. The clean water accumulates here until it is displaced through the crossover pipe connected to the Chlorination Chamber.

CHLORINATION CHAMBER

The clean water flowing out of the crossover pipe is directed through the PVC Chlorine Tablet Feeder located at the end of the cross over pipe. Here the clean water will come in contact with the Chlorine Disinfecting Tablets prior to entering into the Chlorination Chamber where it is held for a residence time sufficient to complete the disinfectant and final stage of the biological treatment process.

DISCHARGE

The disinfected water is then discharged overboard through a gravity overboard discharge connection. No internal pump is required if the AHEAD TANK is installed above the water line. However, if the AHEAD TANK is installed below the water line of the vessel it will be necessary to install an Automatic Waste Water Discharge System (This unit is sold separately). Ahead Sanitation Systems Inc. recommends the BEHIND TANK, a fully self-contained Automatic Waste Water Discharge System. The BEHIND TANK is constructed, and designed to be connected to the discharge of the AHEAD TANK at the same gravity water flow level. The BEHIND TANK comes complete with a Sump Pump (110 VAC or 220 VAC, single phase 60Hz), a Vertical Float Switch and Check Valve, all inside a Durable, Lightweight, Corrosion Proof and Compact, 18” X 18” X 18” LLPE polyethylene material tank.

AHEAD TANK FEATURES & BENEFITS

Meets USCG Certification and IMO Standards Worldwide

Lightweight

Durable / Reliable

Simple to Install

Odor Free Operation

Uses Fresh or Salt Water

Gravity Overboard Discharge

Compact / Small Footprint

Corrosion Proof

Easy to Operate

Low Maintenance

Chemical Resistant

No Internal pump necessary

U.S.C.G Certified Marine Sanitation Device

MSD Model
Number of People ( 24 hours)
Disinfection System
Flowrate (gal. per day)
USCG Approval No.
AT-6T
6
Tablet
56 gallons
159.015/9971/0
AT-12T
12
Tablet
88 gallons
159.015/9972/0
AT-16T
16
Chlorine Solution
88 gallons
159.015/9973/0
AT-20T
20
Chlorine Solution
110 gallons
159.015/9974/0